Analog IO Module

This is the lineup of DIASYS Netmation analog modules.

Check the PDF file for details.

Name Overview
Analog Input FXAIM01 (486 KB) Insulation Inputs: 8 (0 - 20mA / 4 - 20mA)
FXAIM01C (500 KB) Insulation Inputs: 8 (0 - 20mA / 4 - 20mA)
AD Converter Redundancy
FXAIM02 (496 KB) Transmitter Inputs: 8
(0 - 20mA / 4 - 20mA)
Distributor Type (DC24V)
FXAIM02C (522 KB) Transmitter Inputs: 8
(0 - 20mA / 4 - 20mA)
Distributor Type (DC24V)
AD Converter Redundancy
FXAIM03 (513 KB) Insulation Inputs: 8 (DC0 - 5V / DC1 - 5V)
FXAIM03C (519 KB) Insulation Inputs: 8 (DC0 - 5V / DC1 - 5V)
AD Converter Redundancy
FXAIM04A-UP (232 KB) Thermocouple Inputs: 8 (-16mV - 80mV)
  • RTD Inputs for Cold Junction Compensation: 1
    Thermocouple Type: T, R, J, K, E
    Disconnection Detection: Burn-up when disconnected
FXAIM04A-DW (311 KB) Thermocouple Inputs: 8 (-16mV - 80mV)
  • RTD Inputs for Cold Junction Compensation: 1
    Thermocouple Type: T, R, J, K, E
    Disconnection Detection: Burn-down when disconnected
FXAIM04B-UP (330 KB) Thermocouple Inputs: 8 (-8mV - 38mV)
  • RTD Inputs for Cold Junction Compensation: 1
    Thermocouple Type: T, R, J, K, E
    Disconnection Detection: Burn-up when disconnected
FXAIM04B-DW (245 KB) Thermocouple Inputs: 8 (-8mV - 38mV)
  • RTD Inputs for Cold Junction Compensation: 1
    Thermocouple Type: T, R, J, K, E
    Disconnection Detection: Burn-down when disconnected
FXAIM04C-UP (249 KB) Thermocouple Inputs: 8 (-16mV - 80mV)
  • RTD Inputs for Cold Junction Compensation: 1
    Thermocouple Type: T, R, J, K, E
    Disconnection Detection: Burn-up when disconnected
    AD Converter Redundancy
FXAIM04C-DW (249 KB) Thermocouple Inputs: 8 (-16mV - 80mV)
  • RTD Inputs for Cold Junction Compensation: 1
    Thermocouple Type: T, R, J, K, E
    Disconnection Detection: Burn-down when disconnected
    AD Converter Redundancy
FXAIM04D-DW (249 KB) Thermocouple Inputs: 8 (-8mV - 40mV)
  • RTD Inputs for Cold Junction Compensation: 1
    Thermocouple Type: T, R, J, K, E
    Disconnection Detection: Burn-down when disconnected
    AD Converter Redundancy
FXAIM05A (497 KB) Resistance Temperature Detector (RTD) Inputs: 5
RTD Type: Pt100Ω
Input Range: -100 - 650℃
FXAIM05B (497 KB) Resistance Temperature Detector (RTD) Inputs: 5
RTD Type: Pt100Ω
Input Range: -40 - 60℃
FXAIM05C (523 KB) Resistance Temperature Detector (RTD) Inputs: 5
RTD Type: Pt100Ω
Input Range: -100 - 650℃
AD Converter Redundancy
FXAIM05E (503 KB) Resistance Temperature Detector (RTD) Inputs: 5
RTD Type: Pt100Ω
Input Range: -200 - 200℃
FXAIM06A (495 KB) Resistance Temperature Detector (RTD) Inputs: 5
RTD Type: Cu10Ω (at 25℃)
Input Range: 0 - 130℃
Analog Output FXAOM01A (501 KB) Insulation Outputs: 8 (0 - 20mA / 4 - 20mA)
Load Resistance: 0 - 550Ω
FXAOM01AD-1 (527 KB) Insulation Outputs: 8 (0 - 20mA / 4 - 20mA)
Load Resistance: 0 - 550Ω
Supports redundancy
FXAOM01B (508 KB) Insulation Outputs: 4 (0 - 20mA / 4 - 20mA)
Load Resistance: 0 - 750Ω
FXAOM01BD-1 (527 KB) Insulation Outputs: 4 (0 - 20mA / 4 - 20mA)
Load Resistance: 0 - 750Ω
Supports redundancy