Turbine Control Module
This is the lineup of DIASYS Netmation turbine control modules.
Check the PDF file for details.
Name | Overview | |
---|---|---|
Servo Valve Interface |
FXSVL01A (499 KB) | Valve Position Demand Output: 1 (±20mA) Valve Position Feedback: 1 (LVDT 4wiring 5V/5kHz) |
FXSVL02A (505 KB) | Valve Position Demand Output: 1 (±50mA) Valve Position Feedback: 1 (LVDT 4wiring 5V/5kHz) |
|
FXSVL02B (508 KB) | Valve Position Demand Output: 1 (±50mA / ±60mA) Valve Position Feedback: 1 (LVDT 6wiring 8V/5kHz) |
|
FXSVL02B-8V-1K (506 KB) | Valve Position Demand Output: 1 (±50mA) Valve Position Feedback: 1 (LVDT 6wiring 8V/1kHz) |
|
FXSVL02C-8V-1K (506 KB) | Valve Position Demand Output: 1 (±50mA) Valve Position Feedback: 1 (LVDT 4wiring 8V/1kHz) |
|
FXSVL02C-5V-2.5K (506 KB) | Valve Position Demand Output: 1 (±50mA) Valve Position Feedback: 1 (LVDT 4wiring 5V/2.5kHz) |
|
FXSVT01 (506 KB) | Valve Position Demand Output: 1 (±20mA / 4 - 20mA) Valve Position Feedback: 1 (transmitter 4 - 20mA) |
|
FXSVT02 (504 KB) | Valve Position Demand Output: 1 (±50mA) Valve Position Feedback: 1 (transmitter 4 - 20mA) |
|
FXSVT03 (500 KB) | Valve Position Demand Output: 1 (±0 - 250mA) Valve Position Feedback: 1 (transmitter 4 - 20mA) |
|
FXSVT04 (505 KB) | Valve Position Demand Output: 1 (±0 - 500mA) Valve Position Feedback: 1 (transmitter 4 - 20mA) |
|
OPC (Over Speed Protection) |
FXOPC01 (502 KB) | Turbine Over Speed Protection Control |
FVC (Fast Valving Control) |
FXFVC01 (501 KB) | Turbine High-Speed Valve Control (Fast Valving) |
EOST | FXEOS01 (517 KB) | Turbine Over Speed Trip Function Turbine Speed Input: 1 - 12,000rpm EOST Outputs: 2 |
Turbine Interlock | FXTCL02 (506 KB) | Turbine Interlock Demand Output Turbine Interlock Input |
Gas Turbine Interlock |
FXGTI01 (535 KB) | Gas Turbine Interlock |
Vibration Interface | FXVIM01 (503 KB) | Analog Input ±10V Combustion Pressure Fluctuation Input Combustion Chamber Vibration Input FFT Analysis |
FXVIM02 (503 KB) | Analog Input ±10V Combustion Pressure Fluctuation Input Combustion Chamber Vibration Input FFT Analysis |
|
FXVIM02B (502 KB) | Analog Input 1 - 5V Combustion Pressure Fluctuation Input Combustion Chamber Vibration Input FFT Analysis |
Products
- GTCC
- Steam Power
- IGCC
- Geothermal
-
Gas Turbines
- Product Lineup
- Comparative Performance
-
Technical Information
- Gas Turbines for Mechanical Drive Applications
- Cutting-Edge Elemental Technology Producing 1600°C Class J Gas Turbines
- Development of High-Efficiency Gas Turbine Applying 1600°C Class J Technology
- Combustor Technologies Supporting Stable Operation
- Overview and Verification Status of T-Point 2 Demonstration Facility
- Comprehensive Efforts from Development to Manufacturing
- Summary of Orders
- Development History
- Product Selection Assistant (Middle & small Class)
- Aero-derivative Gas Turbines
- Steam Turbines
- Boilers
- Air Quality Control Systems (AQCS)
- Generators
-
Control Systems
- What is DIASYS?
- DIASYS Netmation / DIASYS Netmation4S
-
DIASYS Optional Products
- IR-S Infrared Flame Detector
- Net IR-S Infrared Flame Detector
- Rail Mounting Net IR-S
- Boiler Tube Leak Detector
- Shaft Vibration Analyzer
- Simulator
- Advanced Combustion Pressure Fluctuation Monitoring System (A-CPFM) / Combustion Pressure Fluctuation Monitoring System (CPFM)
- Multi-Coal Fired Boiler Optimum Control
- DIASYS Solutions
- Fuel Cells
- Others
- Catalogue
- HIACS Series
- Technical Report